Classification through the HSE


Whether you are new to the explosives classification process,  or looking to classify product for the first time in the UK, we can help you understand application process, compile the required evidence, recommend specific testing, and assist with technical assessments in support of applications to the HSE.

Do I need to apply to the HSE for classification?


If you are a manufacturer or importer of explosives into Great Britain, it is your responsibility to ensure that the products have been properly classified. For those under a Defence contract, CLICK HERE!. For all other scenarios, you must either:


  • Hold a valid CAD issued by a Contracting Party to ADR.  This must be kept and be available on demand.

     or;

  • Apply for classification with the HSE, submitting the necessary documentation and supporting evidence for your proposed classification.

How do I apply for classification?


Applications through HSE can be made by post, but the HSE now accept applications with electronic signatures so by far the best method of application is by submitting the appropriate form by email to cad.explosives@hse.gov.uk.


The HSE can assign a classification by one of the following methods:


  • On the basis of UN test results and technical information supplied.
    • By analogy with a similar explosive previously classified by HSE or the Defence Ordnance Safety Regulator (DOSR).
    • On the basis of a sound technical argument supported by appropriate documentary evidence.

     


    • By recognising the classification assigned by the Competent Authority of a country that is not a Contracting Party to ADR.


    • For fireworks that are manufactured in Great Britain or a country that does not have a Competent Authority – UN default classification scheme.


    How long will it take?


    You should allow at least one calendar month for the HSE to review the application and associated evidence.


    Once the Competent Authority has agreed the classification, it issues a Competent Authority Document (CAD) which records the classification granted, and any appropriate conditions.

    Competent Authority Document (CAD)


    The CAD will detail the classification assigned by the Competent Authority and may include specific conditions.


    The explosives will also be added by name and part number to the LOCEF database on the Explosives Web Community.


    Once issued, a CAD is normally permanent and issued without an imposed time limit. However a CAD may be time limited if:


    • The classification is related to fireworks, which are given a 10 year validation period.
    • The classification was issued based on a technical case and in the absence of full UN test results.  These CADs are normally issued for a specific, limited period to allow for further testing or for research and development purposes.